Integral Grommet
Designed to seal openings in new raised floor cutouts prior to the installation of communications or power cabling. Based on measurements at multiple data centers, on average 60% of valuable...
View ArticlePass Through Blanking Panel – 2U
Designed to provide an effective airflow sealing solution when used in conjunction with pullout KVM switches or servers that may be occasionally extracted. Also provides additional rack sealing where...
View ArticleAdjustable Rack Gap Panel
The AisleLok® Adjustable Rack Gap Panel is an ideal solution for closing off gaps between racks, such as those created by building support columns or missing IT racks. For non-metallic surfaces, the...
View ArticlePass Through Blanking Panel – 1U
Designed to provide an effective airflow sealing solution when used in conjunction with pullout KVM switches or servers that may be occasionally extracted. Also provides additional rack sealing where...
View ArticleModular Containment: Bi-Directional Doors
The AisleLok Bi-Directional Doors are a key component in Upsite’s AisleLok Modular Containment solution. The doors can be used with or without the AisleLok Rack Top Baffles; however, for maximum...
View ArticleModular Containment: Rack Top Vertical Baffle
The AisleLok Rack Top Baffles are a key component of Upsite’s AisleLok Modular Containment solution and are available in two configurations: Angular (30° from horizontal) and Vertical (90° from...
View ArticleBlanking Panel – 2U
Designed to effectively seal openings in IT equipment cabinets and control airflow for optimized cooling effectiveness. The HotLok Blanking Panel reduces hotspots and bypass airflow by preventing...
View ArticleModular Containment: Rack Top Angle Baffle
The AisleLok Rack Top Baffles are a key component of Upsite’s AisleLok Modular Containment solution and are available in two configurations: Angular (30° from horizontal) and Vertical (90° from...
View ArticleEnvironmental Monitoring System 200™
The Environmental Monitoring System 200™ is a wired sensor network manager that allows for 4 sensor inputs, allowing the deployment of temperature sensors, temperature/humidity sensors or any...
View ArticleBlanking Panel – 1U
Designed to effectively seal openings in IT equipment cabinets and control airflow for optimized cooling effectiveness. The HotLok Blanking Panel reduces hotspots and bypass airflow by preventing...
View ArticleEMS 300™ – Wireless Temperature and Humidity Sensor
The EMS 300 Wireless Temperature and Humidity Sensor is a high resolution battery-operated digital wireless temperature and humidity sensor with a 418 MHz, FCC-certifi ed radio transmitter. The...
View ArticleEMS 300™ – Wireless Temperature Sensor
The EMS 300 Wireless Temperature Sensor is a battery operated digital temperature sensor with a microprocessor controlled 418 MHz, FCC-certified radio transmitter. The 300-TSR-001 sensor provides many...
View ArticleEnvironmental Monitoring System 300™
The EnergyLok Environmental Monitoring System 300™ is a wireless sensor network manager that receives and aggregates signals from up to 150 wireless sensors that can be displayed in a centralized easy...
View Article1010/4040 Cover with Safety Stripe
Designed to seal KoldLok 1010/4040 Grommet openings while cables are waiting to be installed. Lays on top of the inner frame lip of a 1010/4040 grommet without the use of any tools. Bright yellow and...
View ArticleSplitLok™ Square Raised Floor Grommet
Designed to seal small openings in new or existing raised floor cutouts used for communications or power cabling. Based on measurements at multiple data centers, on average 48% of valuable conditioned...
View ArticleSplitLok™ Integral Raised Floor Grommet
Designed to seal openings in new or existing raised floor cutouts used for communications or power cabling. Based on measurements at multiple data centers, on average 48% of valuable conditioned air is...
View ArticleSwitchFix – SF001-PR2
Network switch equipment typically sits at the top and back portion of the server rack. This placement makes it difficult for cold air from the cold aisle to travel from the front of the rack to the...
View ArticleSwitchFix – SF001-PR1
Network switch equipment typically sits at the top and back portion of the server rack. This placement makes it difficult for cold air from the cold aisle to travel from the front of the rack to the...
View ArticleMagnetic Under Rack Panel
The Magnetic Under Rack Panel by Upsite is a quick and easy way to improve airflow management by either blocking bypass airflow or exhaust air recirculation. It employs a unique sealing technology...
View ArticleCustom Imprinted Blanking Panels
Custom Imprinted Blanking Panels allow you to customize blanking panels with your own logos or slogans. This is a low-cost way to add a personalized look into any data center. Colocation facilities can...
View Article